Axus PA-08 Manual de Serviço Página 128

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 252
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 127
SERVICE MANUAL TNC 415B/425
Page 123
Issue: 20.08.95
When the override potentiometer is turned to the right, the control outputs an analogue voltage which is
increased proportionally to the servo lag up to a maximum value of 10V. The control operates correctly,
if a voltage of 10V ± 0.1V can be measured at the test adapter with the multimeter. If no voltage can be
measured, the analogue output of the logic unit is probably defective.
Measuring Setup to Check the Analogue Outputs
servo
amplifier
DIGITAL
logic unit
X8
test adapter
multimeter
5.15V
the cable between nominal
value output and servo amplifier !
Disconnect
X8 Nominal value output for 1, 2, 3, 4, 5, S
flange socket with female insert (15-pin)
Pin No. Signal Pin No. Signal
1 analogue output 1 11 0V analogue output 2
3 analogue output 2 13 0V analogue output 3
5 analogue output 3 14 0V analogue output 4
7 analogue output 4 6 0V analogue output 5
4 analogue output 5 15 0V analogue output S axis
8 analogue output S axis housing external shield = housing
9 0V analogue output 1 2, 10, 12
do not assign
*
Observe the safety instructions!