Function MP
No. Bit
A B C Input AE-6
Entry value
Parameter with multiple
function
Memory function for axis
direction keys
7680
0

0 = not stored
+1 = stored
%00011111
Re-approaching the contour
1

0 = inactive
+2 = active
Block scan
2

0 = inactive
+4 = active
Interruption of block scan by
"STOP" or by M06
3

0 = interruption
+8 = no interruption
Include dwell time during block
scan to change the direction of
rotation in a "tapping" cycle
4

0 = dwell time is waited to end
+16 = dwell time is not waited to end
Start calculation with block scan
5

0 = start from cursor position
+32 = start from beginning of program
Tool length for blocks with surface
normal vector
6-
0 = without DR2 from the tool table
+64 = with DR2 from the tool table
Bit reserved
7--
R H
1.0 TNC
415B/425
Machine Parameters MP 7680 08.05.95 5.2 73